MAX (overflow sensor, 4-20mA)

MAX is a hanging sensor and is used to detect/alarming high level of liquid in the separator/settling tank. The sensor allows to distinguish liquid from the air, where the fluid can also be a liquid petroleum. Generating an alarm signal is formed by immersing the sensor in the liquid.

Technical Data

Supply voltage: 10V
Current consumption: 9mA – 15mA
Cable: Length 5 m, oil resistant, type: OZ-BL_2x0.75
Working temperature: -30°C ÷ +60°C
Ambient temperature: -30°C ÷ +60°C
Degree of protection: IP 68
Dimensions: Roller, fi 24mm, height 102mm
Mass with cable: 260 g
Mounting method: Vertical
Zone / ATEX Explosion Proof: Zone 0 / II 1G Ex ia IIB T4 Ga
ATEX compliant: EN 60079-0, EN 60079-11, EN 60079-26
EU examination certificate: KOMAG 18ATEX0262X
Intrinsic safety parameters of the power circuit: Ui = 13 V; Ii = 0,18 A; Ci ≈ 0,1; Li = 68 µH; Pi = 1,05 W
CE conformity: Directive EMC 2004/108/WE
EMC/immunity: PN-EN 50130-4:2012, PN-EN 61000-6-1:2008
EMC/ immunity: PN-EN 55022:2011, PN-EN 61000-6-
3:2008+A1:2012

Order by 2PM to get delivered next working day! We use 24 hours service with carriers in most cases so that you can get your order delivered on time.

There is £4.99 charge for delivery under £50 Orders. Additional charges will be imposed by our couriers for delivery to remote area, a surcharge may be levied to cover carriage to these areas.

Max

Dowiedz się więcej

MAX (overflow sensor, 4-20mA)

MAX is a hanging sensor and is used to detect/alarming high level of liquid in the separator/settling tank. The sensor allows to distinguish liquid from the air, where the fluid can also be a liquid petroleum. Generating an alarm signal is formed by immersing the sensor in the liquid.

Product request.

MAX (overflow sensor, 4-20mA)

MAX is a hanging sensor and is used to detect/alarming high level of liquid in the separator/settling tank. The sensor allows to distinguish liquid from the air, where the fluid can also be a liquid petroleum. Generating an alarm signal is formed by immersing the sensor in the liquid.

Technical Data

Supply voltage: 10V
Current consumption: 9mA – 15mA
Cable: Length 5 m, oil resistant, type: OZ-BL_2x0.75
Working temperature: -30°C ÷ +60°C
Ambient temperature: -30°C ÷ +60°C
Degree of protection: IP 68
Dimensions: Roller, fi 24mm, height 102mm
Mass with cable: 260 g
Mounting method: Vertical
Zone / ATEX Explosion Proof: Zone 0 / II 1G Ex ia IIB T4 Ga
ATEX compliant: EN 60079-0, EN 60079-11, EN 60079-26
EU examination certificate: KOMAG 18ATEX0262X
Intrinsic safety parameters of the power circuit: Ui = 13 V; Ii = 0,18 A; Ci ≈ 0,1; Li = 68 µH; Pi = 1,05 W
CE conformity: Directive EMC 2004/108/WE
EMC/immunity: PN-EN 50130-4:2012, PN-EN 61000-6-1:2008
EMC/ immunity: PN-EN 55022:2011, PN-EN 61000-6-
3:2008+A1:2012